Expert Commercial HVAC & Refrigeration Services in Cranston, RI
When it comes to HVAC and refrigeration services in Cranston, RI, Serve S is the trusted name. Our clients value our prompt response times and the fact that we're available 24/7. You can rely on us to answer the phone no matter when you call. With our expertise in swift, reliable repairs and extensive experience in replacing and installing commercial HVAC units, refrigerators, freezers, and more, Serve S is the go-to choice for getting your business back on track swiftly and effectively. We serve businesses across a variety of industries, from restaurant refrigeration to HVAC for multinational corporations.
Cut Your Business's Energy Consumption With Serve S
Looking to save some money on your business's energy bill? Look no further than Serve S! Our energy management services are designed to help your business reduce its resource usage while also lowering your monthly expenses. We work closely with energy companies to find the latest rebates and incentives, so you can take advantage of every possible opportunity to save money.
We install top-quality, efficient HVAC units to help reduce the amount of energy required to cool and heat your business. Additionally, we equip your HVAC system with timers, sensors, and other automation components to make sure that your hard-earned dollars aren't being wasted. With Serve S on your side, you can start saving money and become more energy-efficient today!
Give us a call at 781-352-3382 to schedule service today!
Recent Jobs and Reviews in Cranston,
Job Locations and Reviews
Performed routine maintenance on a Carrier WeatherMaker 7.5 Ton 208/230V 3 Phase Rooftop Unit in Boston, MA. Inspected components, cleaned the condenser coils, and tested the refrigerant charge. All systems are functioning well, and the customer is satisfied with the service.
Performed comprehensive maintenance on a Carrier 48HC rooftop unit at a local office building. Cleaned condenser coils using Nu-Calgon Evap Pow'r-C. Replaced clogged air filters with MERV 13 pleated filters. Inspected and tightened electrical connections with Klein Tools torque screwdriver. Lubricated fan motors using Supco synthetic lubricant. Checked refrigerant charge with Fieldpiece SMAN460 digital manifold. Calibrated Honeywell T6 Pro thermostat for optimal performance.
Repaired a Kolpak walk-in refrigerator today. Diagnosed faulty Copeland Scroll compressor using Fluke 87V multimeter. Replaced compressor and Sporlan filter drier. Evacuated system with JB Industries DV-142N vacuum pump. Recharged with R-404A refrigerant using Yellow Jacket 42006 manifold gauge set. Installed new Dixell XR75CX digital controller. Tested system operation, verifying proper temperature maintenance and defrost cycles.
Completed a commercial energy audit. Used a Fluke 1730 Energy Logger to monitor energy consumption and identify inefficiencies. Inspected HVAC systems, lighting, and insulation. Utilized a Testo 875-2i thermal imager to detect heat loss and pinpoint insulation issues. Provided a detailed report with recommendations for energy-saving improvements to enhance overall efficiency and reduce operational costs.
Repaired Trane XR16 air conditioner in Attleboro, MA commercial space. Replaced faulty compressor and recharged system with R-410A refrigerant. Installed new Honeywell thermostat for improved control. Conducted thorough testing to verify optimal system operation and climate control performance.
Performed commercial zoned AC repair. Diagnosed an issue with the Trane Varitrac zoning system. Replaced a faulty zone controller and recalibrated the dampers. Used a Fluke 179 Multimeter to test electrical connections and a Bacharach H10 Pro leak detector to check for refrigerant leaks. Ensured each zone was cooling effectively and the system was running efficiently.
This morning, I repaired a commercial HVAC system experiencing inconsistent cooling. I identified a faulty TXV (Thermostatic Expansion Valve) and replaced it with a Sporlan valve. Using a digital manifold gauge, I recharged the system with R-410A refrigerant to the correct levels. I also checked and recalibrated the building’s VAV (Variable Air Volume) boxes to ensure even temperature distribution. Finally, I inspected the air handler and cleaned the evaporator coils for optimal performance.
I installed a new Carrier 48HC-D high-efficiency rooftop unit today. First, I secured the 20-ton unit to the commercial building's roof curb per specifications. The thermostat control wiring was connected, and refrigerant linesets were carefully evacuated using a Yellowjacket recovery machine. With a tight vacuum achieved, I charged the system with R-410A refrigerant following Carrier's subcooling targets. The economizer was adjusted for proper ventilation operation.
I completed a repair on a Trane Voyager commercial rooftop unit today. The 15-ton gas/electric unit was experiencing low cooling capacity. Upon inspection, the condenser coils were severely fouled with cottonwood seed debris. Using a 4000 PSI pressure washer, I thoroughly cleaned the coils. The condenser fan motors were seized, so I replaced them with new Genteq motors. After a full system evacuation, I recharged with R-410A to factory specifications. The Trane unit's airflow, superheat, and subcooling were brought back within recommended parameters. Proper cooling is now restored to the commercial space.
I installed a new Hussmann RL4N-G refrigerated merchandiser today. First, I leveled and sealed the unit per manufacturer specifications. The pre-charged refrigeration system was evacuated and leak tested using a Fieldpiece LS3X heated sensor leak detector. Then, the R-404A refrigerant charge was adjusted to achieve optimal superheat and subcooling values. The digital thermostat was calibrated for precise temperature control.
I repaired a commercial HVAC system experiencing airflow issues. I replaced the faulty blower motor with a Genteq 1/2 HP motor and adjusted the belt tension. Using a manometer, I checked and calibrated the system's static pressure to ensure optimal airflow. Finally, I inspected the filters and ductwork to confirm there were no additional blockages or issues.
I repaired a True TFM-72 upright commercial freezer today. The issue was faulty defrost cycle operation. I replaced the defrost timer and thermostat, performed an evacuation, and recharged the system with R-404A refrigerant. The evaporator coils were cleaned using NuCalgon Evap-Fresh No-Rinse condenser cleaner. After adjusting the temperature controller, the freezer is maintaining optimal temperature range.
Earlier this month, in Boston, MA, during an annual tune-up and maintenance session for a commercial client's HVAC system, I discovered a significant airflow blockage in a Carrier Infinity system. The blockage was caused by a heavily soiled filter and accumulation within the ducts. I replaced the old filter with a new HEPA filter and performed a thorough cleaning of the ducts. Additionally, I recalibrated the system's Honeywell programmable thermostat to ensure efficient operation. Post-maintenance testing confirmed the system is now running efficiently, with improved air quality and circulation.
This morning in Boston, MA, annual maintenance call for customer. I thoroughly inspected an HVAC system and here are my findings: The return air temperature was 73°F and the supply air was 53°F, resulting in a good 20° temperature split. The total external static pressure was 0.7 WC, with the return at 0.4 WC and supply at 0.3 WC - I recommend checking and replacing the air filter. The blower wheel, evaporator coil, blower run capacitor, and all gas safety controls were clean and functioning properly. The flame sensor was cleaned during the inspection. Both the condenser fan and compressor run capacitors tested within normal tolerance ranges. I have no other additional notes, as overall the HVAC system is in good operating condition without any major issues present.
Responded to a no cooling call in Boston, MA this week. Upon inspection, discovered frozen evaporator coils on the Carrier 25HBC5 air handler. Performed static pressure checks which revealed high external static pressure at 0.9" WC, likely due to dirty air filters. Changed filters and performed complete air flow inspection. Evaporator coil had also lost charge. Evacuated remaining refrigerant, replaced filter drier, and recharged with 7 lbs of R-410A to factory specifications. Cycle tested, ensuring proper superheat/subcooling. Customer now enjoying 20°F temperature split and cool, dehumidified air flow throughout home.
Today in Attleboro, MA, I repaired an HVAC system for a commercial client. The issue involved a malfunctioning Trane XR16 air conditioner. I replaced a faulty compressor and addressed low refrigerant levels by recharging the system with R-410A. Additionally, I installed a new Honeywell thermostat to enhance control and efficiency. System functionality was confirmed through rigorous testing to ensure optimal operation and climate control within the commercial space.
I responded to a service call for a malfunctioning walk-in freezer in Salem, MA earlier this week. Upon arrival, I measured the return air temperature at 28°F, well above the desired setpoint. I performed system diagnostics and determined the issue was a failed evaporator fan motor. I sourced and replaced the 1/2 HP PSC motor and its capacitor, which resolved the malfunction. I evacuated refrigerant lines and recharged them with R-404A to factory specifications, ensuring the freezer maintained -10°F and preserved the client's perishable inventory. I also recommended adding strip curtains to reduce air infiltration and improve energy efficiency.
Conducted maintenance on a Trane YSC060 rooftop air handling unit. Replaced worn compressor contactors and recharged with R-410A refrigerant. Installed programmable Honeywell FocusPro thermostat, utilizing its advanced air management algorithms. Verified proper airflow across evaporator coil and inspected condenser fan motors. System now operating within manufacturer specifications.
I just completed an HVAC repair for a commercial customer in Boston, MA. The issue was a clogged air filter, which was restricting airflow and causing the system to run inefficiently. I replaced the filter with the recommended Flanders PrecisionAire model to restore proper air circulation and system performance.
Routine maintenance on the Carrier WeatherMaker 7.5 Ton 208/230V 3 Phase Rooftop Unit for a customer in Boston, MA. The service included inspecting components, cleaning the condenser coils, and testing the refrigerant charge. Everything looks great, customer is pleased.
I just finished performing routine maintenance on the Daikin 3 Ton Light Commercial 14 SEER Packaged Air Conditioner for a customer in Attleboro, MA. The service included inspecting components, cleaning the condenser coils, and testing the refrigerant charge. Upon startup, I detected a refrigerant leak that required recharging the system to bring it back to proper operating levels.
I performed routine HVAC maintenance for a commercial client in Providence, RI today. This involved inspecting components, cleaning the system, and checking refrigerant levels. During the service, I discovered a worn fan belt that was causing reduced airflow. I promptly replaced the belt to optimize system efficiency.
I just completed an HVAC repair job for a commercial customer in Providence, RI. The issue was a malfunctioning thermostat that was causing inconsistent temperatures throughout the building. I diagnosed the problem, replaced the faulty thermostat, and recalibrated the system to restore proper climate control.
I installed a new commercial refrigeration system at a facility in Concord, NH today. This entailed properly wiring the unit, calibrating the temperature controls, and testing for any leaks. I also repaired an issue with a malfunctioning compressor on another refrigerator on-site. Ensuring reliable cold storage is critical for this business.
Repairing a furnace for a new customer in Salem, MA, I diagnosed and replaced a faulty igniter. After installing the new igniter, I tested the furnace to ensure proper ignition and heating functionality.