Commercial HVAC and Refrigeration Service for Boston-Area Businesses
When your commercial HVAC system or refrigeration system falters, it always seems to choose the most inconvenient moment — like during Bostons’ notorious seasonal extremes. Sweltering heatwaves and bone-chilling frost are when commercial air conditioning and heating systems are most prone to breakdowns.
Our dedicated fleet of emergency HVAC technicians are ready to help. Round-the-clock service, 365 days a year, ensures that your operations remain uninterrupted, no matter what the weather throws your way.
Experience the difference with a partner who values your business climate as much as you do. Reach out to Serve S 24 hours a day — where your comfort is our command. Call (781) 352-3382 or contact us online for commerical HVAC and refrigeration system service near Boston.
We Listen, We Respond, We React
Since our inception in 2013, Serve S has become a cornerstone of the Boston business community’s building maintenance. We’ve built a steadfast reputation on the principles of reliability, swift response times, expert knowledge, proactive management, and honest communication with our clients. Our commitment to exceptional service is unwavering and recognized by those we serve.
Our team, comprised of consummate commercial HVAC professionals, is anything but static. We take immense pride in ensuring their skills are honed through ongoing training on cutting-edge equipment, the latest procedures, and industry innovations. This continuous professional development means any issue your commerical HVAC system encounters is not just temporarily patched up, but efficiently resolved upon the first visit, safeguarding against future setbacks.
Trust in Serve S to sustain your commercial space’s comfort and productivity with an assurance of quality and professionalism that is unparalleled.
Commerical Air Conditioning & Heating Service and Repair for Businesses in the Greater Boston Area
Our commercial HVAC service in Boston is dedicated to providing top-notch commercial air conditioning and heating solutions for businesses. Here are the key features of our service:
- Comprehensive HVAC Services: We offer a wide range of services including installation, repair, and maintenance.
- Client Diversity: Our current client base includes businesses of all sizes, from large corporations to small enterprises. We have the expertise to cater to the unique HVAC needs of different businesses.
- Speed and Efficiency: We understand the importance of minimizing disruptions to your operations. Our team is committed to being fast and efficient, ensuring that your HVAC systems are up and running in a timely manner.
- Respect for Your Time: We value your company’s time and work diligently to complete our HVAC services within agreed-upon deadlines. We prioritize punctuality and strive to minimize any inconvenience caused during our service visits.
With our commercial heating and cooling services, you can trust that we will deliver reliable and effective solutions tailored to your specific requirements. Count on us to keep your business comfortable and ensure optimal indoor climate control.
Foodservice Refrigeration for Boston-Area Restaurants
Serve S’s restaurant refrigeration service offers a range of services designed to meet the refrigeration needs of food service establishments:
- Sales: We provide a wide selection of high-quality food service coolers, freezers, display cases, ice makers, and more.
- Installation: Our skilled technicians ensure proper installation of refrigeration equipment, maximizing its efficiency and longevity.
- Replacement: When it’s time to upgrade or replace your existing refrigeration systems, we offer seamless replacement services tailored to your requirements.
- Repair: Our team is equipped to handle repairs for all types of refrigeration equipment, resolving issues promptly and effectively.
- Maintenance: We offer comprehensive maintenance plans to keep your refrigeration systems in optimal condition, reducing the risk of breakdowns and extending their lifespan.
At Serve S, we prioritize customer satisfaction and aim to minimize downtime. That’s why we strive to respond to service calls within 4 hours, with the possibility of even quicker response times. In fact, we’ve been known to get there in an hour or less!
That’s just part of why our clients keep recommending us to their associates. Our highly qualified technicians perform fast, efficient work, ensuring your business is back up and running smoothly. Trust Serve S’s restaurant refrigeration service for reliable solutions that meet your specific needs.
Energy Optimization for Businesses in Boston
At Serve S, our energy management service is designed to help businesses conserve energy and reduce costs.
Here’s how we can assist you:
- Collaborating with Energy Companies: We work closely with energy companies to identify and leverage the best available rebates and incentives for energy-efficient upgrades. By taking advantage of these programs, we help you optimize your system while maximizing cost savings.
- Efficient System Optimization: Our team specializes in optimizing HVAC systems with efficient units that meet your specific requirements. We assess your current setup and recommend upgrades that can enhance energy efficiency, ensuring your system operates at its best while consuming less energy.
- Timers and Sensors: To further enhance energy savings, we install timers and sensors that enable precise control over your HVAC system. These devices automatically adjust settings based on occupancy, ambient conditions, and time of day, allowing for substantial reductions in energy consumption and ultimately leading to significant savings on energy bills.
Serve S’s energy management service aims to provide tailored solutions that promote energy conservation while improving your bottom line. With our expertise, you can achieve greater energy efficiency, reduce your environmental impact, and enjoy the benefits of lower energy costs.
For more information about any of our offerings, or to schedule service, feel free to give us a call at 781-352-3382 today!
Recent Jobs and Reviews in Boston, MA
Job Locations and Reviews
I repaired a walk-in cooler for a grocery store. The evaporator fan motor was malfunctioning, causing temperature fluctuations. I replaced the fan motor with a new one from Copeland and tested the system. The refrigeration unit resumed maintaining a steady temperature for food storage.
I responded to a commercial heating issue in a warehouse. The Lennox furnace was experiencing ignition failure, leaving the building without heat. Upon inspection, I found a cracked heat exchanger and faulty igniter. I replaced the heat exchanger with a new one from Lennox and installed a new igniter. I also cleaned the burner assembly and tested the unit for carbon monoxide leakage. After completing repairs, I conducted a full system test to verify proper operation. The heating system was restored to optimal performance, providing efficient and safe heat throughout the warehouse space.
I installed a new commercial HVAC system for a retail store. The system included a York 10-ton rooftop unit with a variable-speed compressor. I mounted the unit on the roof, connected the ductwork, and wired the control systems. I also installed a programmable Honeywell thermostat to improve energy efficiency. After installation, I charged the system with R-410A refrigerant and calibrated the thermostat. I ran multiple tests to ensure even cooling throughout the store, and verified the zoning system was functioning properly. The new system is now providing reliable heating and cooling for the business.
I replaced a faulty compressor on a commercial air conditioning unit. The unit had been running inefficiently, causing inconsistent cooling throughout the building. I installed a new Copeland Scroll compressor and replaced the refrigerant with R-410A. After testing for leaks and ensuring proper airflow, the system was restored to full operation, providing consistent cooling once again.
I installed a new Goodman 5-ton rooftop AC unit for a commercial office. I positioned the unit, connected the electrical lines, and sealed the ductwork. I installed a Johnson Controls thermostat to enhance temperature control. After testing airflow and checking for leaks, the new unit provided optimal cooling for the office space, improving employee comfort.
Repaired Trane Intellipak SXHFC commercial chiller. Diagnosed faulty electronic expansion valve (EEV). Removed old Sporlan SEI-30 valve, installed new SEI-30 with updated software. Recalibrated valve using Trane Tracer software. Checked refrigerant charge, adjusted superheat. Chiller now maintaining proper leaving water temperature.
Replaced faulty compressor in Carrier 48HC rooftop unit. Recovered R-410A refrigerant, removed old compressor, installed new Copeland ZP51K5E-PFV scroll compressor. Brazed connections using oxy-acetylene torch, pressure tested with nitrogen, vacuumed system, and recharged. Checked amperage draw and superheat/subcooling. Unit now cooling properly.
I installed a new Carrier 48HC-D high-efficiency rooftop unit today. First, I secured the 20-ton unit to the commercial building's roof curb per specifications. The thermostat control wiring was connected, and refrigerant linesets were carefully evacuated using a Yellowjacket recovery machine. With a tight vacuum achieved, I charged the system with R-410A refrigerant following Carrier's subcooling targets. The economizer was adjusted for proper ventilation operation.
I completed a repair on a Trane Voyager commercial rooftop unit today. The 15-ton gas/electric unit was experiencing low cooling capacity. Upon inspection, the condenser coils were severely fouled with cottonwood seed debris. Using a 4000 PSI pressure washer, I thoroughly cleaned the coils. The condenser fan motors were seized, so I replaced them with new Genteq motors. After a full system evacuation, I recharged with R-410A to factory specifications. The Trane unit's airflow, superheat, and subcooling were brought back within recommended parameters. Proper cooling is now restored to the commercial space.
I installed a new Hussmann RL4N-G refrigerated merchandiser today. First, I leveled and sealed the unit per manufacturer specifications. The pre-charged refrigeration system was evacuated and leak tested using a Fieldpiece LS3X heated sensor leak detector. Then, the R-404A refrigerant charge was adjusted to achieve optimal superheat and subcooling values. The digital thermostat was calibrated for precise temperature control.
I repaired a commercial HVAC system experiencing airflow issues. I replaced the faulty blower motor with a Genteq 1/2 HP motor and adjusted the belt tension. Using a manometer, I checked and calibrated the system's static pressure to ensure optimal airflow. Finally, I inspected the filters and ductwork to confirm there were no additional blockages or issues.
Earlier this month, in Boston, MA, during an annual tune-up and maintenance session for a commercial client's HVAC system, I discovered a significant airflow blockage in a Carrier Infinity system. The blockage was caused by a heavily soiled filter and accumulation within the ducts. I replaced the old filter with a new HEPA filter and performed a thorough cleaning of the ducts. Additionally, I recalibrated the system's Honeywell programmable thermostat to ensure efficient operation. Post-maintenance testing confirmed the system is now running efficiently, with improved air quality and circulation.
This morning in Boston, MA, annual maintenance call for customer. I thoroughly inspected an HVAC system and here are my findings: The return air temperature was 73°F and the supply air was 53°F, resulting in a good 20° temperature split. The total external static pressure was 0.7 WC, with the return at 0.4 WC and supply at 0.3 WC - I recommend checking and replacing the air filter. The blower wheel, evaporator coil, blower run capacitor, and all gas safety controls were clean and functioning properly. The flame sensor was cleaned during the inspection. Both the condenser fan and compressor run capacitors tested within normal tolerance ranges. I have no other additional notes, as overall the HVAC system is in good operating condition without any major issues present.
Responded to a no cooling call in Boston, MA this week. Upon inspection, discovered frozen evaporator coils on the Carrier 25HBC5 air handler. Performed static pressure checks which revealed high external static pressure at 0.9" WC, likely due to dirty air filters. Changed filters and performed complete air flow inspection. Evaporator coil had also lost charge. Evacuated remaining refrigerant, replaced filter drier, and recharged with 7 lbs of R-410A to factory specifications. Cycle tested, ensuring proper superheat/subcooling. Customer now enjoying 20°F temperature split and cool, dehumidified air flow throughout home.
I just completed an HVAC repair for a commercial customer in Boston, MA. The issue was a clogged air filter, which was restricting airflow and causing the system to run inefficiently. I replaced the filter with the recommended Flanders PrecisionAire model to restore proper air circulation and system performance.
Routine maintenance on the Carrier WeatherMaker 7.5 Ton 208/230V 3 Phase Rooftop Unit for a customer in Boston, MA. The service included inspecting components, cleaning the condenser coils, and testing the refrigerant charge. Everything looks great, customer is pleased.
Maintaining a deep freeze for a loyal customer in Jamaica Plain, MA. The tasks were items such as cleaning condenser coils, inspecting and adjusting temperature controls, testing door seals, and lubricating hinges for smooth operation. Additionally, I checked and replaced worn-out gaskets as needed.
Just completed a commercial repair on a True T-49F Reach-In Freezer in Boston, MA. Diagnosed a faulty thermostat causing inconsistent temperature regulation. Customer is very happy with the repair, and business can continue as usual.
Just completed a commercial repair on a Rheem Prestige Series Gas Furnace at a Boston, MA facility. Identified a malfunctioning gas valve disrupting the heating process. The quick replacement brought back the furnace's optimal functionality, guaranteeing continuous operation through the chilly season. Our goal is to offer dependable HVAC solutions tailored to businesses' needs.
Addressed a furnace issue at a Dorchester, MA establishment, working on a Carrier Performance 80 Gas Furnace. Diagnosed a faulty blower motor causing insufficient airflow. With expertise and precision, we ensure businesses stay comfortable and operational, providing dependable HVAC solutions.
Check out the new DDC controls and operating system upgrade. Make sure the dampers and actuators are operating.
Checked the reach in refrigerated sandwich case and refrigerated meat cooler to make sure maintaining correct temperatures.